ICS 29.240.01K 42备案号:40050-2013中华人民共和国电力行业标准DL / T 1220 — 2013串联电容器补偿装置交接试验及验收规范Code for hand-over tests of series capacitor installation2013-03-07 发布2013-08-01 实施国家能源局发 布DL / T 1220 — 2013I目次前言·········································· Ⅱ1范围········································· 12规范性引用文件···································· 13术语和定义······································ 14总则········································· 25一次设备交接试验··································· 36二次设备交接试验·································· 107分系统试验····································· 128系统试验······································ 13DL / T 1220 — 2013II前言为规范串联电容器补偿装置交接试验和验收等技术环节,促进串联电容器补偿装置的技术进步,提高装置的设计、制造、运行和维护水平,特制定本标准。本标准由中国电力企业联合会提出。本标准由电力行业电能质量及柔性输电标准化技术委员会归口。本标准起草单位:国网智能电网研究院、国家电网公司华北分部、国网湖北省电力公司电力科学研究院、中国南方电网有限责任公司超高压输电公司、国网冀北电力有限公司检修分公司、中国南方电网有限责任公司超高压输电公司柳州局、国网江苏省电力公司检修分公司徐州分部、中国南方电网有限责任公司超高压输电公司百色局、中国电力工程顾问集团西北电力设计院。本标准主要起草人:石泽京、牛晓民、康健、戴朝波、黄雄辉、祁胜利、李庆光、王邵闽、熊斌、韦宇、项力恒。本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市白广路二条一号,100761)。DL / T 1220 — 20131串联电容器补偿装置交接试验及验收规范1范围本标准规定了串联电容器补偿装置(简称串补装置)现场交接试验应遵循的基本原则、试验项目、验收标准等。本标准适用于 220kV~500kV 电压等级的串联电容器补偿装置,其他电压等级可参照执行。2规范性引用文件下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB 311.1绝缘配合第 1 部分:定义、原则和规则GB 50150—2006电气装置安装工程电气设备交接试验标准GB 50171—2012电气装置安装工程盘、柜及二次回路接线施工及验收规范GB/T 6115.1—2008电力系统用串联电容器第 1 部分:总则GB/T 6115.2—2002电力系统用串联电容器第 2 部分:串联电容器组用保护设备GB/T 8905—2012六氟化硫电气设备中气体管理和检测导则GB/T 15145—2008输电线路保护装置通用技术条件GB/T 16927.2高电压试验技术第 2 部分:测量系统GB/T 28565—2012高压交流串联电容器用旁路开关DL/T 365—2010串联电容器补偿装置控制保护系统现场检验规程DL/T 366—2010串联电容器补偿装置一次设备预防性试验规程DL/T 478—2010继电保护和安全自动装置通用技术条件DL/T 995—2006继电保护和电网安全自动装置检验规程DL/T 1010.4—2006高压静止无功补偿装置第 4 部分:现场试验3术语和定义下列术语和定义适用于本标准。3.1串联电容器补偿装置series capacitor installation (SC)串联在输电线路中,由电容器组及其保护、控制等辅助设备组成的装置,简称串补装置或串补,主要有固定串联电容器补偿装置(简称固定串补)和晶闸管控制串联电容器补偿装置(简称可控串补)。3.2(电容器的)额定电容rated ca.